14. Traffic Metering and Policing API
14.1. Overview
This is the generic API for the Quality of Service (QoS) Traffic Metering and Policing (MTR) of Ethernet devices. This API is agnostic of the underlying HW, SW or mixed HW-SW implementation.
The main features are:
- Part of DPDK rte_ethdev API
- Capability query API
- Metering algorithms: RFC 2697 Single Rate Three Color Marker (srTCM), RFC 2698 and RFC 4115 Two Rate Three Color Marker (trTCM)
- Policer actions (per meter output color): recolor, drop
- Statistics (per policer output color)
14.2. Configuration steps
The metering and policing stage typically sits on top of flow classification, which is why the MTR objects are enabled through a special “meter” action.
The MTR objects are created and updated in their own name space (rte_mtr
)
within the librte_ethdev
library. Whether an MTR object is private to a
flow or potentially shared by several flows has to be specified at its
creation time.
Once successfully created, an MTR object is hooked into the RX processing path of the Ethernet device by linking it to one or several flows through the dedicated “meter” flow action. One or several “meter” actions can be registered for the same flow. An MTR object can only be destroyed if there are no flows using it.
14.3. Run-time processing
Traffic metering determines the color for the current packet (green, yellow, red) based on the previous history for this flow as maintained by the MTR object. The policer can do nothing, override the color the packet or drop the packet. Statistics counters are maintained for MTR object, as configured.
The processing done for each input packet hitting an MTR object is:
- Traffic metering: The packet is assigned a color (the meter output color) based on the previous traffic history reflected in the current state of the MTR object, according to the specific traffic metering algorithm. The traffic metering algorithm can typically work in color aware mode, in which case the input packet already has an initial color (the input color), or in color blind mode, which is equivalent to considering all input packets initially colored as green.
- Policing: There is a separate policer action configured for each meter
output color, which can:
- Drop the packet.
- Keep the same packet color: the policer output color matches the meter output color (essentially a no-op action).
- Recolor the packet: the policer output color is set to a different color
than the meter output color. The policer output color is the output color
of the packet, which is set in the packet meta-data (i.e. struct
rte_mbuf::sched::color
).
- Statistics: The set of counters maintained for each MTR object is configurable and subject to the implementation support. This set includes the number of packets and bytes dropped or passed for each output color.