15. I40E Poll Mode Driver
The I40E PMD (librte_pmd_i40e) provides poll mode driver support for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
15.1. Features
Features of the I40E PMD are:
- Multiple queues for TX and RX
- Receiver Side Scaling (RSS)
- MAC/VLAN filtering
- Packet type information
- Flow director
- Cloud filter
- Checksum offload
- VLAN/QinQ stripping and inserting
- TSO offload
- Promiscuous mode
- Multicast mode
- Port hardware statistics
- Jumbo frames
- Link state information
- Link flow control
- Mirror on port, VLAN and VSI
- Interrupt mode for RX
- Scattered and gather for TX and RX
- Vector Poll mode driver
- DCB
- VMDQ
- SR-IOV VF
- Hot plug
- IEEE1588/802.1AS timestamping
- VF Daemon (VFD) - EXPERIMENTAL
- Dynamic Device Personalization (DDP)
- Queue region configuration
15.2. Prerequisites
- Identifying your adapter using Intel Support and get the latest NVM/FW images.
- Follow the DPDK Getting Started Guide for Linux to setup the basic DPDK environment.
- To get better performance on Intel platforms, please follow the “How to get best performance with NICs on Intel platforms” section of the Getting Started Guide for Linux.
- Upgrade the NVM/FW version following the Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux if needed.
15.3. Pre-Installation Configuration
15.3.1. Config File Options
The following options can be modified in the config
file.
Please note that enabling debugging options may affect system performance.
CONFIG_RTE_LIBRTE_I40E_PMD
(defaulty
)Toggle compilation of the
librte_pmd_i40e
driver.CONFIG_RTE_LIBRTE_I40E_DEBUG_*
(defaultn
)Toggle display of generic debugging messages.
CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC
(defaulty
)Toggle bulk allocation for RX.
CONFIG_RTE_LIBRTE_I40E_INC_VECTOR
(defaultn
)Toggle the use of Vector PMD instead of normal RX/TX path. To enable vPMD for RX, bulk allocation for Rx must be allowed.
CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC
(defaultn
)Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF
(default64
)Number of queues reserved for PF.
CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM
(default4
)Number of queues reserved for each VMDQ Pool.
CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL
(default-1
)Interrupt Throttling interval.
15.3.2. Runtime Config Options
Number of Queues per VF
(default4
)The number of queue per VF is determined by its host PF. If the PCI address of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues per VF is 4 by default.
Support multiple driver
(defaultdisable
)There was a multiple driver support issue during use of 700 series Ethernet Adapter with both Linux kernel and DPDK PMD. To fix this issue,
devargs
parametersupport-multi-driver
is introduced, for example:-w 84:00.0,support-multi-driver=1
With the above configuration, DPDK PMD will not change global registers, and will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between DPDK and Linux Kernel.
15.4. Driver compilation and testing
Refer to the document compiling and testing a PMD for a NIC for details.
15.5. SR-IOV: Prerequisites and sample Application Notes
Load the kernel module:
modprobe i40e
Check the output in dmesg:
i40e 0000:83:00.1 ens802f0: renamed from eth0
Bring up the PF ports:
ifconfig ens802f0 up
Create VF device(s):
Echo the number of VFs to be created into the
sriov_numvfs
sysfs entry of the parent PF.Example:
echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
Assign VF MAC address:
Assign MAC address to the VF using iproute2 utility. The syntax is:
ip link set <PF netdev id> vf <VF id> mac <macaddr>
Example:
ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
Assign VF to VM, and bring up the VM. Please see the documentation for the I40E/IXGBE/IGB Virtual Function Driver.
Running testpmd:
Follow instructions available in the document compiling and testing a PMD for a NIC to run testpmd.
Example output:
... EAL: PCI device 0000:83:00.0 on NUMA socket 1 EAL: probe driver: 8086:1572 rte_i40e_pmd EAL: PCI memory mapped at 0x7f7f80000000 EAL: PCI memory mapped at 0x7f7f80800000 PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a Interactive-mode selected Configuring Port 0 (socket 0) ... PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0. ... Port 0: 68:05:CA:26:85:84 Checking link statuses... Port 0 Link Up - speed 10000 Mbps - full-duplex Done testpmd>
15.6. Sample Application Notes
15.6.1. Vlan filter
Vlan filter only works when Promiscuous mode is off.
To start testpmd
, and add vlan 10 to port 0:
./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
...
testpmd> set promisc 0 off
testpmd> rx_vlan add 10 0
15.6.2. Flow Director
The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues. The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
The default input set of each flow type is:
ipv4-other : src_ip_address, dst_ip_address
ipv4-frag : src_ip_address, dst_ip_address
ipv4-tcp : src_ip_address, dst_ip_address, src_port, dst_port
ipv4-udp : src_ip_address, dst_ip_address, src_port, dst_port
ipv4-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
verification_tag
ipv6-other : src_ip_address, dst_ip_address
ipv6-frag : src_ip_address, dst_ip_address
ipv6-tcp : src_ip_address, dst_ip_address, src_port, dst_port
ipv6-udp : src_ip_address, dst_ip_address, src_port, dst_port
ipv6-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
verification_tag
l2_payload : ether_type
The flex payload is selected from offset 0 to 15 of packet’s payload by default, while it is masked out from matching.
Start testpmd
with --disable-rss
and --pkt-filter-mode=perfect
:
./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
--rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
Add a rule to direct ipv4-udp
packet whose dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32
to queue 1:
testpmd> flow_director_filter 0 mode IP add flow ipv4-udp \
src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
fwd pf queue 1 fd_id 1
Check the flow director status:
testpmd> show port fdir 0
######################## FDIR infos for port 0 ####################
MODE: PERFECT
SUPPORTED FLOW TYPE: ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
l2_payload
FLEX PAYLOAD INFO:
max_len: 16 payload_limit: 480
payload_unit: 2 payload_seg: 3
bitmask_unit: 2 bitmask_num: 2
MASK:
vlan_tci: 0x0000,
src_ipv4: 0x00000000,
dst_ipv4: 0x00000000,
src_port: 0x0000,
dst_port: 0x0000
src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
FLEX PAYLOAD SRC OFFSET:
L2_PAYLOAD: 0 1 2 3 4 5 6 ...
L3_PAYLOAD: 0 1 2 3 4 5 6 ...
L4_PAYLOAD: 0 1 2 3 4 5 6 ...
FLEX MASK CFG:
ipv4-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv4-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv4-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv4-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv4-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv6-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv6-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv6-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv6-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
ipv6-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
l2_payload: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
guarant_count: 1 best_count: 0
guarant_space: 512 best_space: 7168
collision: 0 free: 0
maxhash: 0 maxlen: 0
add: 0 remove: 0
f_add: 0 f_remove: 0
Delete all flow director rules on a port:
testpmd> flush_flow_director 0
15.6.3. Floating VEB
The Intel® Ethernet Controller X710 and XL710 Family support a feature called “Floating VEB”.
A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term for functionality that allows local switching between virtual endpoints within a physical endpoint and also with an external bridge/network.
A “Floating” VEB doesn’t have an uplink connection to the outside world so all switching is done internally and remains within the host. As such, this feature provides security benefits.
In addition, a Floating VEB overcomes a limitation of normal VEBs where they cannot forward packets when the physical link is down. Floating VEBs don’t need to connect to the NIC port so they can still forward traffic from VF to VF even when the physical link is down.
Therefore, with this feature enabled VFs can be limited to communicating with each other but not an outside network, and they can do so even when there is no physical uplink on the associated NIC port.
To enable this feature, the user should pass a devargs
parameter to the
EAL, for example:
-w 84:00.0,enable_floating_veb=1
In this configuration the PMD will use the floating VEB feature for all the VFs created by this PF device.
Alternatively, the user can specify which VFs need to connect to this floating
VEB using the floating_veb_list
argument:
-w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
In this example VF1
, VF3
and VF4
connect to the floating VEB,
while other VFs connect to the normal VEB.
The current implementation only supports one floating VEB and one regular VEB. VFs can connect to a floating VEB or a regular VEB according to the configuration passed on the EAL command line.
The floating VEB functionality requires a NIC firmware version of 5.0 or greater.
15.6.4. Dynamic Device Personalization (DDP)
The Intel® Ethernet Controller X*710 support a feature called “Dynamic Device Personalization (DDP)”, which is used to configure hardware by downloading a profile to support protocols/filters which are not supported by default. The DDP functionality requires a NIC firmware version of 6.0 or greater.
Current implementation supports MPLSoUDP/MPLSoGRE/GTP-C/GTP-U/PPPoE/PPPoL2TP, steering can be used with rte_flow API.
Load a profile which supports MPLSoUDP/MPLSoGRE and store backup profile:
testpmd> ddp add 0 ./mpls.pkgo,./backup.pkgo
Delete a MPLS profile and restore backup profile:
testpmd> ddp del 0 ./backup.pkgo
Get loaded DDP package info list:
testpmd> ddp get list 0
Display information about a MPLS profile:
testpmd> ddp get info ./mpls.pkgo
15.6.5. Input set configuration
Input set for any PCTYPE can be configured with user defined configuration, For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
testpmd> port config 0 pctype 43 hash_inset clear all
testpmd> port config 0 pctype 43 hash_inset set field 13
testpmd> port config 0 pctype 43 hash_inset set field 14
testpmd> port config 0 pctype 43 hash_inset set field 15
15.6.6. Queue region configuration
The Ethernet Controller X710/XL710 supports a feature of queue regions
configuration for RSS in the PF, so that different traffic classes or
different packet classification types can be separated to different
queues in different queue regions. There is an API for configuration
of queue regions in RSS with a command line. It can parse the parameters
of the region index, queue number, queue start index, user priority, traffic
classes and so on. Depending on commands from the command line, it will call
i40e private APIs and start the process of setting or flushing the queue
region configuration. As this feature is specific for i40e only private
APIs are used. These new test_pmd
commands are as shown below. For
details please refer to Testpmd Application User Guide.
testpmd> set port (port_id) queue-region region_id (value) \
queue_start_index (value) queue_num (value)
testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
testpmd> set port (port_id) queue-region UP (value) region_id (value)
testpmd> set port (port_id) queue-region flush (on|off)
testpmd> show port (port_id) queue-region
15.7. Limitations or Known issues
15.7.1. MPLS packet classification on X710/XL710
For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC. The L2 Payload flow type in flow director can be used to classify MPLS packet by using a command in testpmd like:
- testpmd> flow_director_filter 0 mode IP add flow l2_payload ether
- 0x8847 flexbytes () fwd pf queue <N> fd_id <M>
With the NIC firmware version 5.0 or greater, some limited MPLS support is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no new packet type, no classification or offload are possible. With this change, L2 Payload flow type in flow director cannot be used to classify MPLS packet as with previous firmware versions. Meanwhile, the Ethertype filter can be used to classify MPLS packet by using a command in testpmd like:
- testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype
- 0x8847 fwd queue <M>
15.7.2. 16 Byte RX Descriptor setting on DPDK VF
Currently the VF’s RX descriptor mode is decided by PF. There’s no PF-VF
interface for VF to request the RX descriptor mode, also no interface to notify
VF its own RX descriptor mode.
For all available versions of the i40e driver, these drivers don’t support 16
byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
descriptor. The reason is that the RX descriptor is already set to 32 byte by
the i40e kernel driver. That is to say, user should keep
CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n
in config file.
In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
byte, as the PF driver.
The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX descriptor mode. Or the VF RX will not work.
15.7.3. Receive packets with Ethertype 0x88A8
Due to the FW limitation, PF can receive packets with Ethertype 0x88A8 only when floating VEB is disabled.
15.7.4. Incorrect Rx statistics when packet is oversize
When a packet is over maximum frame size, the packet is dropped. However the Rx statistics, when calling rte_eth_stats_get incorrectly shows it as received.
15.7.5. VF & TC max bandwidth setting
The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel. The dehavior is different when handling per VF and per TC max bandwidth setting. When enabling per VF max bandwidth, SW will check if per TC max bandwidth is enabled. If so, return failure. When enabling per TC max bandwidth, SW will check if per VF max bandwidth is enabled. If so, disable per VF max bandwidth and continue with per TC max bandwidth setting.
15.7.6. TC TX scheduling mode setting
There’re 2 TX scheduling modes for TCs, round robin and strict priority mode. If a TC is set to strict priority mode, it can consume unlimited bandwidth. It means if APP has set the max bandwidth for that TC, it comes to no effect. It’s suggested to set the strict priority mode for a TC that is latency sensitive but no consuming much bandwidth.
15.7.7. VF performance is impacted by PCI extended tag setting
To reach maximum NIC performance in the VF the PCI extended tag must be enabled. The DPDK I40E PF driver will set this feature during initialization, but the kernel PF driver does not. So when running traffic on a VF which is managed by the kernel PF driver, a significant NIC performance downgrade has been observed (for 64 byte packets, there is about 25% linerate downgrade for a 25G device and about 35% for a 40G device).
For kernel version >= 4.11, the kernel’s PCI driver will enable the extended tag if it detects that the device supports it. So by default, this is not an issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be enabled using the steps below.
Get the current value of the PCI configure register:
setpci -s <XX:XX.X> a8.w
Set bit 8:
value = value | 0x100
Set the PCI configure register with new value:
setpci -s <XX:XX.X> a8.w=<value>
15.7.8. Vlan strip of VF
The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
15.7.9. DCB function
DCB works only when RSS is enabled.
15.7.10. Global configuration warning
I40E PMD will set some global registers to enable some function or set some configure. Then when using different ports of the same NIC with Linux kernel and DPDK, the port with Linux kernel will be impacted by the port with DPDK. For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A with DPDK, then the configuration will also impact port B in the NIC with kernel driver, which don’t want to use the TPID. So PMD reports warning to clarify what is changed by writing global register.
15.8. High Performance of Small Packets on 40G NIC
As there might be firmware fixes for performance enhancement in latest version of firmware image, the firmware update might be needed for getting high performance. Check with the local Intel’s Network Division application engineers for firmware updates. Users should consult the release notes specific to a DPDK release to identify the validated firmware version for a NIC using the i40e driver.
15.8.1. Use 16 Bytes RX Descriptor Size
As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
Configuration of CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC
in config files can be changed to use 16 bytes size RX descriptors.
15.8.2. High Performance and per Packet Latency Tradeoff
Due to the hardware design, the interrupt signal inside NIC is needed for per
packet descriptor write-back. The minimum interval of interrupts could be set
at compile time by CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL
in configuration files.
Though there is a default configuration, the interval could be tuned by the
users with that configuration item depends on what the user cares about more,
performance or per packet latency.
15.9. Example of getting best performance with l3fwd example
The following is an example of running the DPDK l3fwd
sample application to get high performance with an
Intel server platform and Intel XL710 NICs.
The example scenario is to get best performance with two Intel XL710 40GbE ports. See Fig. 15.1 for the performance test setup.
Add two Intel XL710 NICs to the platform, and use one port per card to get best performance. The reason for using two NICs is to overcome a PCIe Gen3’s limitation since it cannot provide 80G bandwidth for two 40G ports, but two different PCIe Gen3 x8 slot can. Refer to the sample NICs output above, then we can select
82:00.0
and85:00.0
as test ports:82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583] 85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
Connect the ports to the traffic generator. For high speed testing, it’s best to use a hardware traffic generator.
Check the PCI devices numa node (socket id) and get the cores number on the exact socket id. In this case,
82:00.0
and85:00.0
are both in socket 1, and the cores on socket 1 in the referenced platform are 18-35 and 54-71. Note: Don’t use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical cores from different cores (e.g core18 and core19).Bind these two ports to igb_uio.
As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
The DPDK sample application
l3fwd
will be used for performance testing, with using two ports for bi-directional forwarding. Compile thel3fwd sample
with the default lpm mode.The command line of running l3fwd would be something like the following:
./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \ -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding, core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
Configure the traffic at a traffic generator.
- Start creating a stream on packet generator.
- Set the Ethernet II type to 0x0800.