17. LiquidIO VF Poll Mode Driver
The LiquidIO VF PMD library (librte_pmd_lio) provides poll mode driver support for Cavium LiquidIO® II server adapter VFs. PF management and VF creation can be done using kernel driver.
More information can be found at Cavium Official Website.
17.1. Supported LiquidIO Adapters
- LiquidIO II CN2350 210SV/225SV
- LiquidIO II CN2360 210SV/225SV
17.2. Pre-Installation Configuration
The following options can be modified in the config
file.
Please note that enabling debugging options may affect system performance.
CONFIG_RTE_LIBRTE_LIO_PMD
(defaulty
)Toggle compilation of LiquidIO PMD.
CONFIG_RTE_LIBRTE_LIO_DEBUG_DRIVER
(defaultn
)Toggle display of generic debugging messages.
CONFIG_RTE_LIBRTE_LIO_DEBUG_INIT
(defaultn
)Toggle display of initialization related messages.
CONFIG_RTE_LIBRTE_LIO_DEBUG_RX
(defaultn
)Toggle display of receive fast path run-time messages.
CONFIG_RTE_LIBRTE_LIO_DEBUG_TX
(defaultn
)Toggle display of transmit fast path run-time messages.
CONFIG_RTE_LIBRTE_LIO_DEBUG_MBOX
(defaultn
)Toggle display of mailbox messages.
CONFIG_RTE_LIBRTE_LIO_DEBUG_REGS
(defaultn
)Toggle display of register reads and writes.
17.3. SR-IOV: Prerequisites and Sample Application Notes
This section provides instructions to configure SR-IOV with Linux OS.
Verify SR-IOV and ARI capabilities are enabled on the adapter using
lspci
:lspci -s <slot> -vvv
Example output:
[...] Capabilities: [148 v1] Alternative Routing-ID Interpretation (ARI) [...] Capabilities: [178 v1] Single Root I/O Virtualization (SR-IOV) [...] Kernel driver in use: LiquidIO
Load the kernel module:
modprobe liquidio
Bring up the PF ports:
ifconfig p4p1 up ifconfig p4p2 up
Change PF MTU if required:
ifconfig p4p1 mtu 9000 ifconfig p4p2 mtu 9000
Create VF device(s):
Echo number of VFs to be created into
"sriov_numvfs"
sysfs entry of the parent PF.echo 1 > /sys/bus/pci/devices/0000:03:00.0/sriov_numvfs echo 1 > /sys/bus/pci/devices/0000:03:00.1/sriov_numvfs
Assign VF MAC address:
Assign MAC address to the VF using iproute2 utility. The syntax is:
ip link set <PF iface> vf <VF id> mac <macaddr>
Example output:
ip link set p4p1 vf 0 mac F2:A8:1B:5E:B4:66
Assign VF(s) to VM.
The VF devices may be passed through to the guest VM using qemu or virt-manager or virsh etc.
Example qemu guest launch command:
./qemu-system-x86_64 -name lio-vm -machine accel=kvm \ -cpu host -m 4096 -smp 4 \ -drive file=<disk_file>,if=none,id=disk1,format=<type> \ -device virtio-blk-pci,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \ -device vfio-pci,host=03:00.3 -device vfio-pci,host=03:08.3
Running testpmd
Refer to the document compiling and testing a PMD for a NIC to run
testpmd
application.Note
Use
igb_uio
instead ofvfio-pci
in VM.Example output:
[...] EAL: PCI device 0000:03:00.3 on NUMA socket 0 EAL: probe driver: 177d:9712 net_liovf EAL: using IOMMU type 1 (Type 1) PMD: net_liovf[03:00.3]INFO: DEVICE : CN23XX VF EAL: PCI device 0000:03:08.3 on NUMA socket 0 EAL: probe driver: 177d:9712 net_liovf PMD: net_liovf[03:08.3]INFO: DEVICE : CN23XX VF Interactive-mode selected USER1: create a new mbuf pool <mbuf_pool_socket_0>: n=171456, size=2176, socket=0 Configuring Port 0 (socket 0) PMD: net_liovf[03:00.3]INFO: Starting port 0 Port 0: F2:A8:1B:5E:B4:66 Configuring Port 1 (socket 0) PMD: net_liovf[03:08.3]INFO: Starting port 1 Port 1: 32:76:CC:EE:56:D7 Checking link statuses... Port 0 Link Up - speed 10000 Mbps - full-duplex Port 1 Link Up - speed 10000 Mbps - full-duplex Done testpmd>
17.4. Limitations
17.4.1. VF MTU
VF MTU is limited by PF MTU. Raise PF value before configuring VF for larger packet size.
17.4.2. VLAN offload
Tx VLAN insertion is not supported and consequently VLAN offload feature is marked partial.
17.4.3. Ring size
Number of descriptors for Rx/Tx ring should be in the range 128 to 512.
17.4.4. CRC striping
LiquidIO adapters strip ethernet FCS of every packet coming to the host
interface. So, CRC will be stripped even when the rxmode.hw_strip_crc
member is set to 0 in struct rte_eth_conf
.