17. ThunderX NICVF Poll Mode Driver
The ThunderX NICVF PMD (librte_pmd_thunderx_nicvf) provides poll mode driver support for the inbuilt NIC found in the Cavium ThunderX SoC family as well as their virtual functions (VF) in SR-IOV context.
More information can be found at Cavium Networks Official Website.
17.1. Features
Features of the ThunderX PMD are:
- Multiple queues for TX and RX
- Receive Side Scaling (RSS)
- Packet type information
- Checksum offload
- Promiscuous mode
- Multicast mode
- Port hardware statistics
- Jumbo frames
- Link state information
- Scattered and gather for TX and RX
- VLAN stripping
- SR-IOV VF
- NUMA support
- Multi queue set support (up to 96 queues (12 queue sets)) per port
17.2. Supported ThunderX SoCs
- CN88xx
- CN81xx
- CN83xx
17.3. Prerequisites
- Follow the DPDK Getting Started Guide for Linux to setup the basic DPDK environment.
17.4. Pre-Installation Configuration
17.4.1. Config File Options
The following options can be modified in the config
file.
Please note that enabling debugging options may affect system performance.
CONFIG_RTE_LIBRTE_THUNDERX_NICVF_PMD
(defaultn
)By default it is enabled only for defconfig_arm64-thunderx-* config. Toggle compilation of the
librte_pmd_thunderx_nicvf
driver.CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_INIT
(defaultn
)Toggle display of initialization related messages.
CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_RX
(defaultn
)Toggle display of receive fast path run-time message
CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_TX
(defaultn
)Toggle display of transmit fast path run-time message
CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_DRIVER
(defaultn
)Toggle display of generic debugging messages
CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_MBOX
(defaultn
)Toggle display of PF mailbox related run-time check messages
17.4.2. Driver Compilation
To compile the ThunderX NICVF PMD for Linux arm64 gcc target, run the following “make” command:
cd <DPDK-source-directory>
make config T=arm64-thunderx-linuxapp-gcc install
17.5. Linux
17.5.1. Running testpmd
This section demonstrates how to launch testpmd
with ThunderX NIC VF device
managed by librte_pmd_thunderx_nicvf
in the Linux operating system.
Load
vfio-pci
driver:modprobe vfio-pci
Enable VFIO-NOIOMMU mode (optional):
echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode
Note
VFIO-NOIOMMU is required only when running in VM context and should not be enabled otherwise. See also SR-IOV: Prerequisites and sample Application Notes.
Bind the ThunderX NIC VF device to
vfio-pci
loaded in the previous step:Setup VFIO permissions for regular users and then bind to
vfio-pci
:./tools/dpdk-devbind.py --bind vfio-pci 0002:01:00.2
Start
testpmd
with basic parameters:./arm64-thunderx-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 0002:01:00.2 \ -- -i --disable-hw-vlan-filter --no-flush-rx \ --port-topology=loop
Example output:
... PMD: rte_nicvf_pmd_init(): librte_pmd_thunderx nicvf version 1.0 ... EAL: probe driver: 177d:11 rte_nicvf_pmd EAL: using IOMMU type 1 (Type 1) EAL: PCI memory mapped at 0x3ffade50000 EAL: Trying to map BAR 4 that contains the MSI-X table. Trying offsets: 0x40000000000:0x0000, 0x10000:0x1f0000 EAL: PCI memory mapped at 0x3ffadc60000 PMD: nicvf_eth_dev_init(): nicvf: device (177d:11) 2:1:0:2 PMD: nicvf_eth_dev_init(): node=0 vf=1 mode=tns-bypass sqs=false loopback_supported=true PMD: nicvf_eth_dev_init(): Port 0 (177d:11) mac=a6:c6:d9:17:78:01 Interactive-mode selected Configuring Port 0 (socket 0) ... PMD: nicvf_dev_configure(): Configured ethdev port0 hwcap=0x0 Port 0: A6:C6:D9:17:78:01 Checking link statuses... Port 0 Link Up - speed 10000 Mbps - full-duplex Done testpmd>
17.5.2. SR-IOV: Prerequisites and sample Application Notes
Current ThunderX NIC PF/VF kernel modules maps each physical Ethernet port automatically to virtual function (VF) and presented them as PCIe-like SR-IOV device. This section provides instructions to configure SR-IOV with Linux OS.
Verify PF devices capabilities using
lspci
:lspci -vvv
Example output:
0002:01:00.0 Ethernet controller: Cavium Networks Device a01e (rev 01) ... Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI) ... Capabilities: [180 v1] Single Root I/O Virtualization (SR-IOV) ... Kernel driver in use: thunder-nic ...
Note
Unless
thunder-nic
driver is in use make sure your kernel config includesCONFIG_THUNDER_NIC_PF
setting.Verify VF devices capabilities and drivers using
lspci
:lspci -vvv
Example output:
0002:01:00.1 Ethernet controller: Cavium Networks Device 0011 (rev 01) ... Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI) ... Kernel driver in use: thunder-nicvf ... 0002:01:00.2 Ethernet controller: Cavium Networks Device 0011 (rev 01) ... Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI) ... Kernel driver in use: thunder-nicvf ...
Note
Unless
thunder-nicvf
driver is in use make sure your kernel config includesCONFIG_THUNDER_NIC_VF
setting.Verify PF/VF bind using
dpdk-devbind.py
:./tools/dpdk-devbind.py --status
Example output:
... 0002:01:00.0 'Device a01e' if= drv=thunder-nic unused=vfio-pci 0002:01:00.1 'Device 0011' if=eth0 drv=thunder-nicvf unused=vfio-pci 0002:01:00.2 'Device 0011' if=eth1 drv=thunder-nicvf unused=vfio-pci ...
Load
vfio-pci
driver:modprobe vfio-pci
Bind VF devices to
vfio-pci
usingdpdk-devbind.py
:./tools/dpdk-devbind.py --bind vfio-pci 0002:01:00.1 ./tools/dpdk-devbind.py --bind vfio-pci 0002:01:00.2
Verify VF bind using
dpdk-devbind.py
:./tools/dpdk-devbind.py --status
Example output:
... 0002:01:00.1 'Device 0011' drv=vfio-pci unused= 0002:01:00.2 'Device 0011' drv=vfio-pci unused= ... 0002:01:00.0 'Device a01e' if= drv=thunder-nic unused=vfio-pci ...
Pass VF device to VM context (PCIe Passthrough):
The VF devices may be passed through to the guest VM using qemu or virt-manager or virsh etc.
librte_pmd_thunderx_nicvf
orthunder-nicvf
should be used to bind the VF devices in the guest VM in VFIO-NOIOMMU mode.Example qemu guest launch command:
sudo qemu-system-aarch64 -name vm1 \ -machine virt,gic_version=3,accel=kvm,usb=off \ -cpu host -m 4096 \ -smp 4,sockets=1,cores=8,threads=1 \ -nographic -nodefaults \ -kernel <kernel image> \ -append "root=/dev/vda console=ttyAMA0 rw hugepagesz=512M hugepages=3" \ -device vfio-pci,host=0002:01:00.1 \ -drive file=<rootfs.ext3>,if=none,id=disk1,format=raw \ -device virtio-blk-device,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \ -netdev tap,id=net0,ifname=tap0,script=/etc/qemu-ifup_thunder \ -device virtio-net-device,netdev=net0 \ -serial stdio \ -mem-path /dev/huge
Refer to section Running testpmd for instruction how to launch
testpmd
application.
17.5.3. Multiple Queue Set per DPDK port configuration
There are two types of VFs:
- Primary VF
- Secondary VF
Each port consists of a primary VF and n secondary VF(s). Each VF provides 8 Tx/Rx queues to a port. When a given port is configured to use more than 8 queues, it requires one (or more) secondary VF. Each secondary VF adds 8 additional queues to the queue set.
During PMD driver initialization, the primary VF’s are enumerated by checking the specific flag (see sqs message in DPDK boot log - sqs indicates secondary queue set). They are at the beginning of VF list (the remain ones are secondary VF’s).
The primary VFs are used as master queue sets. Secondary VFs provide additional queue sets for primary ones. If a port is configured for more then 8 queues than it will request for additional queues from secondary VFs.
Secondary VFs cannot be shared between primary VFs.
Primary VFs are present on the beginning of the ‘Network devices using kernel driver’ list, secondary VFs are on the remaining on the remaining part of the list.
Note
The VNIC driver in the multiqueue setup works differently than other drivers like ixgbe. We need to bind separately each specific queue set device with the
tools/dpdk-devbind.py
utility.Note
Depending on the hardware used, the kernel driver sets a threshold
vf_id
. VFs that try to attached with an id below or equal to this boundary are considered primary VFs. VFs that try to attach with an id above this boundary are considered secondary VFs.
17.5.4. Example device binding
If a system has three interfaces, a total of 18 VF devices will be created on a non-NUMA machine.
Note
NUMA systems have 12 VFs per port and non-NUMA 6 VFs per port.
# tools/dpdk-devbind.py --status Network devices using DPDK-compatible driver ============================================ <none> Network devices using kernel driver =================================== 0000:01:10.0 'Device a026' if= drv=thunder-BGX unused=vfio-pci,uio_pci_generic 0000:01:10.1 'Device a026' if= drv=thunder-BGX unused=vfio-pci,uio_pci_generic 0002:01:00.0 'Device a01e' if= drv=thunder-nic unused=vfio-pci,uio_pci_generic 0002:01:00.1 'Device 0011' if=eth0 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.2 'Device 0011' if=eth1 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.3 'Device 0011' if=eth2 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.4 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.5 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.6 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:00.7 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.0 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.1 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.2 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.3 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.4 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.5 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.6 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:01.7 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:02.0 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:02.1 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic 0002:01:02.2 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic Other network devices ===================== 0002:00:03.0 'Device a01f' unused=vfio-pci,uio_pci_generic
We want to bind two physical interfaces with 24 queues each device, we attach two primary VFs and four secondary queues. In our example we choose two 10G interfaces eth1 (0002:01:00.2) and eth2 (0002:01:00.3). We will choose four secondary queue sets from the ending of the list (0002:01:01.7-0002:01:02.2).
Bind two primary VFs to the
vfio-pci
driver:tools/dpdk-devbind.py -b vfio-pci 0002:01:00.2 tools/dpdk-devbind.py -b vfio-pci 0002:01:00.3
Bind four primary VFs to the
vfio-pci
driver:tools/dpdk-devbind.py -b vfio-pci 0002:01:01.7 tools/dpdk-devbind.py -b vfio-pci 0002:01:02.0 tools/dpdk-devbind.py -b vfio-pci 0002:01:02.1 tools/dpdk-devbind.py -b vfio-pci 0002:01:02.2
The nicvf thunderx driver will make use of attached secondary VFs automatically during the interface configuration stage.
17.6. Limitations
17.6.1. CRC striping
The ThunderX SoC family NICs strip the CRC for every packets coming into the
host interface. So, CRC will be stripped even when the
rxmode.hw_strip_crc
member is set to 0 in struct rte_eth_conf
.
17.6.2. Maximum packet length
The ThunderX SoC family NICs support a maximum of a 9K jumbo frame. The value
is fixed and cannot be changed. So, even when the rxmode.max_rx_pkt_len
member of struct rte_eth_conf
is set to a value lower than 9200, frames
up to 9200 bytes can still reach the host interface.
17.6.3. Maximum packet segments
The ThunderX SoC family NICs support up to 12 segments per packet when working
in scatter/gather mode. So, setting MTU will result with EINVAL
when the