.. Copyright (c) <2016-2017>, Intel Corporation
   All rights reserved.

   Redistribution and use in source and binary forms, with or without
   modification, are permitted provided that the following conditions
   are met:

   - Redistributions of source code must retain the above copyright
     notice, this list of conditions and the following disclaimer.

   - Redistributions in binary form must reproduce the above copyright
     notice, this list of conditions and the following disclaimer in
     the documentation and/or other materials provided with the
     distribution.

   - Neither the name of Intel Corporation nor the names of its
     contributors may be used to endorse or promote products derived
     from this software without specific prior written permission.

   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
   FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
   COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
   INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
   (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
   SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
   HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
   STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
   ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
   OF THE POSSIBILITY OF SUCH DAMAGE.

=================================
VEB Switch and floating VEB Tests
=================================

VEB Switching Introduction
==========================

IEEE EVB tutorial:
http://www.ieee802.org/802_tutorials/2009-11
/evb-tutorial-draft-20091116_v09.pdf

Virtual Ethernet Bridge (VEB) - This is an IEEE EVB term. A VEB is a VLAN
Bridge internal to Fortville that bridges the traffic of multiple VSIs over
an internal virtual network.

Virtual Ethernet Port Aggregator (VEPA) - This is an IEEE EVB term. A VEPA
multiplexes the traffic of one or more VSIs onto a single Fortville Ethernet
port. The biggest difference between a VEB and a VEPA is that a VEB can
switch packets internally between VSIs, whereas a VEPA cannot.

Virtual Station Interface (VSI) - This is an IEEE EVB term that defines
the properties of a virtual machine's (or a physical machine's) connection
to the network. Each downstream v-port on a Fortville VEB or VEPA defines
a VSI. A standards-based definition of VSI properties enables network
management tools to perform virtual machine migration and associated network
re-configuration in a vendor-neutral manner.

My understanding of VEB is that it's an in-NIC switch(MAC/VLAN), and it can
support VF->VF, PF->VF, VF->PF packet forwarding according to the NIC internal
switch. It's similar as Niantic's SRIOV switch.

Floating VEB Introduction
=========================

Floating VEB is based on VEB Switching. It will address 2 problems:

Dependency on PF: When the physical port is link down, the functionality of
the VEB/VEPA will not work normally. Even only data forwarding between the VF
is required, one PF port will be wasted to create the related VEB.

Ensure all the traffic from VF can only forwarding within the VFs connect
to the floating VEB, cannot forward to the outside world.

Prerequisites for VEB testing
=============================

1. Get the pci device id of DUT, for example::

      ./dpdk-devbind.py --st
      0000:05:00.0 'Ethernet Controller X710 for 10GbE SFP+' if=ens785f0 drv=i40e
      unused=

2. Host PF in kernel driver. Create 2 VFs from 1 PF with kernel driver, and
   set the VF MAC address at PF::

      echo 2 > /sys/bus/pci/devices/0000\:05\:00.0/sriov_numvfs
      ./dpdk-devbind.py --st

      0000:05:02.0 'XL710/X710 Virtual Function' unused=
      0000:05:02.1 'XL710/X710 Virtual Function' unused=

      ip link set ens785f0 vf 0 mac 00:11:22:33:44:11
      ip link set ens785f0 vf 1 mac 00:11:22:33:44:12

3. Host PF in DPDK driver. Create 2VFs from 1 PF with dpdk driver::

      ./dpdk-devbind.py -b igb_uio 05:00.0
      echo 2 >/sys/bus/pci/devices/0000:05:00.0/max_vfs
      ./dpdk-devbind.py --st
      0000:05:02.0 'XL710/X710 Virtual Function' unused=i40evf,igb_uio
      0000:05:02.1 'XL710/X710 Virtual Function' unused=i40evf,igb_uio

4. Bind the VFs to dpdk driver::

      ./tools/dpdk-devbind.py -b igb_uio 05:02.0 05:02.1

5. Reserve huge pages memory(before using DPDK)::

      echo 4096 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB
      /nr_hugepages
      mkdir /mnt/huge
      mount -t hugetlbfs nodev /mnt/huge

Test Case: Floating VEB inter VF-VF
===================================

Summary: 1 DPDK PF, then create 2VF, PF in the host running dpdk testpmd,
and VF0 are running dpdk testpmd, VF0 send traffic, and set the packet's
DEST MAC to VF1, check if VF1 can receive the packets. Check Inter VF-VF
MAC switch when PF is link down as well as up.

1. Launch PF testpmd::

      ./testpmd -c 0xf -n 4 --socket-mem 1024,1024
      -w 05:00.0,enable_floating_veb=1 --file-prefix=test1 -- -i
      testpmd> port start all
      testpmd> show port info all

2. VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024
      -w 05:02.0 --file-prefix=test2 -- -i --crc-strip
      testpmd> mac_addr add 0 vf1_mac_address
      testpmd> set fwd rxonly
      testpmd> set promisc all off
      testpmd> start
      testpmd> show port stats all

   VF2, run testpmd::

      ./testpmd -c 0xf00 -n 4 --socket-mem 1024,1024 -w 05:02.1 --file-prefix=test3
      -- -i --crc-strip --eth-peer=0,vf1_mac_address
      testpmd> set fwd txonly
      testpmd> start
      testpmd> show port stats all

3. Check if VF1 can get all the packets. Check the packet content is no
   corrupted. RX-packets=TX-packets, but there is a little RX-error.
   PF receive no packets.

4. Set "testpmd> port stop all" and "testpmd> start" in step2,
   then run the step2-3 again. Get same result.

Test Case: Floating VEB PF can't get traffic from VF
====================================================

Summary: DPDK PF, then create 1VF, PF in the host running dpdk testpmd,
send traffic from PF to VF0, VF0 can't receive any packets;
send traffic from VF0 to PF, PF can't receive any packets either.

1. In PF, launch testpmd::

      ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 -w 05:00.0,enable_floating_veb=1 --file-prefix=test1 -- -i
      testpmd> set fwd rxonly
      testpmd> set promisc all off
      testpmd> port start all
      testpmd> start
      testpmd> show port stats all

2. VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.0 --file-prefix=test2 -- -i --eth-peer=0,pf_mac_addr
      testpmd> set fwd txonly
      testpmd> start
      testpmd> show port stats all

3. Check if PF can not get any packets, so VF1->PF is not working.

4. Set "testpmd> port stop all" in step2, then run the test case again.
   Same result.

5. in the opposite direction, PF->VF1 is not working either.

Test Case: Floating VEB VF can't receive traffic from outside world
===================================================================

Summary: DPDK PF, then create 1VF, send traffic from tester to VF1,
in floating mode, check VF1 can't receive traffic from tester.

1. Start VM1 with VF1, see the prerequisite part.

2. PF, launch testpmd::

      ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 -w 05:00.0,enable_floating_veb=1 --file-prefix=test1 -- -i --eth-peer=0,VF_mac_address
      testpmd> set fwd mac
      testpmd> port start all
      testpmd> start
      testpmd> show port stats all

   VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.0 --file-prefix=test2 -- -i
      testpmd> set fwd rxonly
      testpmd> start
      testpmd> show port stats all

   In tester, run scapy::

      packet=Ether(dst="VF_mac_address")/IP()/UDP()/Raw('x'*20)
      sendp(packet,iface="enp132s0f0")

3. Check if VF1 can not get any packets, so tester->VF1 is not working.

4. Set "testpmd> port stop all" in step2 in Host, then run the test case
   again. Get same result. PF can't receive any packets.

Test Case: Floating VEB VF can not communicate with legacy VEB VF
=================================================================

Summary: DPDK PF, then create 4VFs and 4VMs, VF0,VF2,VF3, floating VEB;
VF1, legacy VEB. Make PF link down(the cable can be plugged out),
VFs in VMs are running dpdk testpmd.

1. VF0 send traffic, and set the packet's DEST MAC to VF1,
   check VF1 can not receive the packets.
2. VF0 send traffic, and set the packet's DEST MAC to VF2,
   check VF2 can receive the packets.
3. VF3 send traffic, and set the packet's DEST MAC to VF2,
   check VF2 can receive the packets.
4. VF1 send traffic, and set the packet's DEST MAC to VF0,
   check VF0 can not receive the packets.

Details:

1. Launch PF testpmd, run testpmd with floating parameters and make the link down::

      ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 \
      \"-w "05:00.0,enable_floating_veb=1,floating_veb_list=0;2-3\" \
      --file-prefix=test1 -- -i
      //VF0, VF2 and VF3in floating VEB, VF1 in legacy VEB

      testpmd> port stop all
      //this step should be executed after vf running testpmd.

      testpmd> show port info all

2. VF0 send traffic, and set the packet's DEST MAC to VF1,
   check VF1 can not receive the packets.

   VF0, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.0 \
      --file-prefix=test2 -- -i --eth-peer=0,vf1_mac_address
      testpmd> set fwd rxonly
      testpmd> mac_addr add 0 vf0_mac_address     //set the vf0_mac_address
      testpmd> start
      testpmd> show port stats all

   VF1, run testpmd::

      ./testpmd -c 0xf00 -n 4 --socket-mem 1024,1024 -w 05:02.1 \
       --file-prefix=test3 -- -i --eth-peer=0,vf1_mac_address
      testpmd> set fwd txonly
      testpmd> mac_addr add 0 vf1_mac_addres
      testpmd> start
      testpmd> show port stats all

   Check VF1 can not get any packets, so VF0->VF1 is not working.
   In the opposite direction, VF1->VF0 is not working either.

3. VF0 send traffic, and set the packet's DEST MAC to VF2,
   check VF2 can receive the packets.

   VF2, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.2 \
      --file-prefix=test2 -- -i
      testpmd> set fwd rxonly
      testpmd> mac_addr add 0 vf2_mac_addres
      testpmd> start
      testpmd> show port stats all

   VF0, run testpmd::

      ./testpmd -c 0xf00 -n 4 --socket-mem 1024,1024 -w 05:02.0 \
       --file-prefix=test3 -- -i --eth-peer=0,vf2_mac_address
      testpmd> set fwd txonly
      testpmd> start
      testpmd> show port stats all

    Check VF2 can get all the packets. Check the packet content is no
    corrupted.  so VF0->VF2 is working.

4. VF2 send traffic, and set the packet's DEST MAC to VF3,
   check VF3 can receive the packets.

5. Set "testpmd> port start all" and "testpmd> start" in step1,
   then run the step2-4 again. same result.

Test Case: PF interaction with Floating VF and legacy VF
========================================================

Summary: DPDK PF, then create 4VFs, VF0 and VF3 is in floating VEB,
VF1 and VF2 is in legacy VEB.

1. Send traffic from VF0 to PF, then check PF will not see any traffic;
2. Send traffic from VF1 to PF, then check PF will receive all the packets.
3. send traffic from tester to VF0, check VF0 can't receive traffic from
   tester.
4. send traffic from tester to VF1, check VF1 can receive all the traffic
   from tester.
5. send traffic from VF1 to VF2, check VF2 can receive all the traffic
   from VF1.

Details:

1. In PF, launch testpmd::

      ./testpmd -c 0xf -n 4 --socket-mem 1024,1024 \
      \"-w 05:00.0,enable_floating_veb=1,floating_veb_list=0;3\" \
      --file-prefix=test1 -- -i
      testpmd> set fwd rxonly
      testpmd> port start all
      testpmd> start
      testpmd> show port stats all

2. VF0, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.0 \
      --file-prefix=test2 -- -i --eth-peer=0,pf_mac_addr
      testpmd> set fwd txonly
      testpmd> start

   Check PF can not get any packets, so VF0->PF is not working.

3. VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.1 \
      --file-prefix=test2 -- -i --eth-peer=0,pf_mac_addr
      testpmd> set fwd txonly
      testpmd> start

   Check PF can get all the packets, so VF1->PF is working.

4. VF0, run testpmd::

     ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.0 --file-prefix=test2 -- -i
      testpmd> mac_addr add 0 VF0_mac_address
      testpmd> set promisc all off
      testpmd> set fwd rxonly
      testpmd> start

   In tester, run scapy::

      packet=Ether(dst="VF0_mac_address")/IP()/UDP()/Raw('x'*20)
      sendp(packet,iface="enp132s0f0")

   Check VF0 can get all the packets, so tester->VF0 is working.

5. VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.1 --file-prefix=test2 -- -i
      testpmd> mac_addr add 0 VF1_mac_address
      testpmd> set promisc all off
      testpmd> set fwd rxonly
      testpmd> start

   In tester, run scapy::

      packet=Ether(dst="VF1_mac_address")/IP()/UDP()/Raw('x'*20)
      sendp(packet,iface="enp132s0f0")

   Check VF1 can get all the packets, so tester->VF1 is working.

6. VF1, run testpmd::

      ./testpmd -c 0xf0 -n 4 --socket-mem 1024,1024 -w 05:02.1 --file-prefix=test2 -- -i
      testpmd> mac_addr add 0 VF1_mac_address
      testpmd> set promisc all off
      testpmd> set fwd rxonly
      testpmd> start

   VF2, run testpmd::

      ./testpmd -c 0xf00 -n 4 --socket-mem 1024,1024 -w 05:02.2 \
      --file-prefix=test3 -- -i --eth-peer=0,VF1_mac_address
      testpmd> set fwd txonly
      testpmd> start

   Check VF1 can get all the packets, so VF2->VF1 is working.
   PF link down, VF2->VF1 can work too.

7. Set "testpmd> port stop all" in step1 in PF, then run the test case
   again.  VF1 and VF2 cannot receive any packets. (because PF link down, and
   PF can't receive any packets. so even if VF2 can't receive any packets.)